![]() |
Extend/retract touch probe |
M23 | Measure current tool |
M24 | Remeasure and store Z Reference in Parameter 942 |
M31 | Signal Nanovea controller to start data collection |
M32 | Signal Nanovea controller to stop data collection |
M40 | Extend touch probe |
M41 | Retract touch probe |
M61 | Probe center of die, set XYZ part zero there |
M62 | Probe surface of die, set Z part zero there |
Parameter | Typical value | Meaning |
---|---|---|
940 | 1.675 | X spacing between touch probe centerline and spindle centerline |
942 | -3.9749 | Z Reference for tool measurement (distance down from home to trip touch probe on tool pad) |
943 | 0.000 | Y spacing between touch probe centerline and spindle centerline |
Location | Use |
---|---|
WCS #1 - #6 (G54-G59) |
Available for machining parts |
Return Point #3 (G30 P3) |
Touch probe aligned over tool touch pad |
Return Point #4 (G30 P4) |
Spindle aligned over tool touch pad (tool-measuring start point) |